ATX6550A
¡¾Features¡¿
Channel size£º650£¨width£©¡Á500£¨high£©mm
------------------------------------------------------------------------
Conveyor speed£º0.22 m/s
------------------------------------------------------------------------
Conveyor belt rated load£º170 kg
------------------------------------------------------------------------
Resolution£º¦µ0.0787 mm
------------------------------------------------------------------------
Spatial resolution£ºLevel£º¦µ1.0 mm,Vertical£º¦µ1.0 mm
------------------------------------------------------------------------
Penetration resolution£º¦µ0.202 mm
------------------------------------------------------------------------
Penetration£º¡Ý 6mm Steel plate
------------------------------------------------------------------------
Film security£ºISO1600 film security
------------------------------------------------------------------------
Leakage dose£º0.12¦ÌGy/h
------------------------------------------------------------------------
Noise level£º55dB
------------------------------------------------------------------------
Power loss£º1.0KW£¨Max£©
------------------------------------------------------------------------
Operating Voltage£º220VAC(¡À10%) 50¡À3Hz
------------------------------------------------------------------------
Working temperature/Humidity£º0¡æ¡«45¡æ£¯20%¡«95% (Not condensing)
------------------------------------------------------------------------
Storage temperature/Humidity£º-20¡æ¡«60¡æ£¯20%¡«95% (Not condensing)
------------------------------------------------------------------------
¡¾X-ray generator parameters¡¿
Beam direction£ºBottom type
------------------------------------------------------------------------
Tube current£º0.4¡«0.5mA£¨Adjustable£©
------------------------------------------------------------------------
Tube voltage£º80 kV£¨Adjustable£©
------------------------------------------------------------------------
Ray divergence angle£º80¡ã
------------------------------------------------------------------------
Cooling/Work cycle£ºSealed oil cooling£¯100£¥
------------------------------------------------------------------------
¡¾Image processing performance¡¿
X-ray sensor£ºL-shaped photodiode array detector(Single energy)£¬12bit Depth.
------------------------------------------------------------------------
Monitor£ºHigh resolution 19 inch LCD display.
------------------------------------------------------------------------
Color image display£º24-bit true color display.
------------------------------------------------------------------------
Edge enhancement£ºThe outline of the object is sharper.
------------------------------------------------------------------------
Super image enhancement£ºThe image details are clearer.
------------------------------------------------------------------------
High penetration display£ºImprove the contrast of bright areas in the image to make the easy-to-penetrate area clearer.
------------------------------------------------------------------------
Low penetration display£ºImprove the contrast of dark areas in the image to make the difficult-to-penetrate area clearer.
------------------------------------------------------------------------
Magnifier£ºPartial magnification function.
------------------------------------------------------------------------
Brighten/Dark£ºIncrease the brightness of the image/Dim the brightness of the image.
------------------------------------------------------------------------
Image pull back/Front pull£ºThe first 20 images are displayed and any image processing can be performed on the current image.
------------------------------------------------------------------------
Image restoration£ºThe image display returns to its original state.
------------------------------------------------------------------------
Image storage£ºSave any image in real time, and perform any image processing and save it continuously.
------------------------------------------------------------------------
Drug Image storage£ºSave any image in real time, and perform any image processing and save it continuously.
------------------------------------------------------------------------
explosive assisted detection£ºIt is more helpful in detecting dangerous goods such as some typical drug explosives.
------------------------------------------------------------------------
ATX6550C
¡¾Features¡¿
Channel size£º650£¨width£©¡Á500£¨high£©mm
-----------------------------------------------------------------------
Conveyor speed£º0.22 m/s
-----------------------------------------------------------------------
Conveyor belt rated load£º170 kg
-----------------------------------------------------------------------
Resolution£º¦µ0.0787 mm
-----------------------------------------------------------------------
Spatial resolution£ºLevel£º¦µ1.0 mm,Vertical£º¦µ1.0 mm
-----------------------------------------------------------------------
Penetration resolution£º¦µ0.202 mm
-----------------------------------------------------------------------
Penetration£º40mm Steel plate
-----------------------------------------------------------------------
Film security£ºISO1600 film security
-----------------------------------------------------------------------
Leakage dose£º0.12¦ÌGy/h
-----------------------------------------------------------------------
Noise level£º55dB
-----------------------------------------------------------------------
Power loss£º1.0KW£¨Max£©
-----------------------------------------------------------------------
Operating Voltage£º220VAC(¡À10%) 50¡À3Hz
-----------------------------------------------------------------------
Working temperature/Humidity£º0¡æ¡«45¡æ£¯20%¡«95% (Not condensing)
-----------------------------------------------------------------------
Storage temperature/Humidity£º-20¡æ¡«60¡æ£¯20%¡«95% (Not condensing)
-----------------------------------------------------------------------
¡¾X-ray generator parameters¡¿
Beam direction£ºBottom type
-----------------------------------------------------------------------
Tube current£º0.4¡«1.2mA£¨Adjustable£©
-----------------------------------------------------------------------
Tube voltage£º100¡«160 kV£¨Adjustable£©
-----------------------------------------------------------------------
Ray divergence angle£º80¡ã
-----------------------------------------------------------------------
Cooling/Work cycle£ºSealed oil cooling£¯100£¥
-----------------------------------------------------------------------
¡¾Image processing performance¡¿
X-ray sensor£ºL-shaped photodiode array detector(Multiple energy)£¬12bit Depth.
-----------------------------------------------------------------------
Monitor£ºHigh resolution 19 inch LCD display.
-----------------------------------------------------------------------
Color image display£º24-bit true color display.
-----------------------------------------------------------------------
Edge enhancement£ºThe outline of the object is sharper.
-----------------------------------------------------------------------
Super image enhancement£ºThe image details are clearer.
-----------------------------------------------------------------------
High penetration display£ºImprove the contrast of bright areas in the image to make the easy-to-penetrate area clearer.
-----------------------------------------------------------------------
Low penetration display£ºImprove the contrast of dark areas in the image to make the difficult-to-penetrate area clearer.
-----------------------------------------------------------------------
Magnifier£ºPartial magnification function.
-----------------------------------------------------------------------
Brighten/Dark£ºIncrease the brightness of the image/Dim the brightness of the image.
-----------------------------------------------------------------------
Image pull back/Front pull£ºThe first 20 images are displayed and any image processing can be performed on the current image.
-----------------------------------------------------------------------
Image restoration£ºThe image display returns to its original state.
-----------------------------------------------------------------------
Image storage£ºSave any image in real time, and perform any image processing and save it continuously.
-----------------------------------------------------------------------
Multi-energy color£ºThe organic matter was shown in orange, the inorganic matter was shown in blue, and the mixture was shown in green.
-----------------------------------------------------------------------
High energy/Low energy: two energy switching displays.
-----------------------------------------------------------------------
Drug Image storage£ºSave any image in real time, and perform any image processing and save it continuously.
-----------------------------------------------------------------------